Please read this operation manual before using the Heat Pump
INSTALLATION AND MAINTENANCE INSTRUCTIONS
AIR SOURCE HEAT PUMP
AWA-SS-10 AWA-SS-12 AWA-SS-16
( 3x400V / 3 / 50Hz )
( 230V / 50HZ )
MODEL :
AWA-SS-6 AWA-SS-8
( ALL IN ONE )
JULY 2009
Vista de pagina 0
1 2 3 4 5 6 ... 53 54

Indice de contenidos

Pagina 1 - AIR SOURCE HEAT PUMP

Please read this operation manual before using the Heat Pump INSTALLATION AND MAINTENANCE INSTRUCTIONSAIR SOURCE HEAT PUMPAWA-SS-10 AWA-SS-12 AWA-

Pagina 2

Pipe connections8Pipe installation must be carried out in accordancewith current norms and directives. The heat pump canoperate up to a return tempera

Pagina 3 - Contents

Pipe connections9Pipe connections for the heat medium side are madeat the top. All required safety devices, shut-off valves(as close to the heat pump

Pagina 4 - System description 2

Pipe connections10How to connect the copper pipesPiping ConnectonAttention :When connectiong the pipe, a suitable pitching spanner must be used. If

Pagina 5 - System description

Pipe connections114. Tighten the cap of two valves.5. Disconnect the power cable from outdoor unit.6. Loose the nut of the connect pipe to the outdoor

Pagina 6 - Refrigerant Circuit

Pipe connections12Pump capacity diagrams, heating medium sidekPa AWA-SS-8AWA-SS-6AWA-SS-10AvailablepressureFlowAWA-SS-12l/s1230.220.440.660.881.101.3

Pagina 7 - OPER. AUTO

Pipe connections13 The pump isadjustable to adjustthe flow: 1, 2, or 3.The pump isadjustable to adjustthe flow: 1, 2, or 3.WILO RS-25/8WILO RL-25/7.5

Pagina 8 - Functions

Electrical connection 14NOTE! Electrical installation and service mustbe carried out under the supervision ofa qualified electrician in accordancewith

Pagina 9 - Transport and storage

Electrical connection15Step1 Step3Step2Step1 Step3Step2Wiring of the terminal (mode one)Wiring of the terminal (mode two)

Pagina 10 - Pipe connections

Electrical connection 16Connecting The Room Temperature SensorConnecting The Outside Temperature SensorOUTP=Defrost temperature sensorOutdoor unitOUTP

Pagina 11

Electrical connection17CWTWITOUTPOCTRTWTT C0MP PA.OUTHPLPCSPGNDEHIN3WV4WVNGNDWCPNOFANNGNDGNDWCP2NLayout of the PCBFrom PCB / CON4 /11,12From PCB / CON

Pagina 13

Electrical connection 18Part of wiring diagram2.5mm2 terminal connectionEH1EH2NEH3NWUVGNDT3T2T1L3L2L1C1uwvcmREDWHITEBLACKFrom AC contactor / L3From AC

Pagina 14

Electrical connection19Wiring Diagram( 230V / 50 HZ )

Pagina 15

Electrical connection20Wiring Diagram ( 3X400V / 3 / 50 HZ )

Pagina 16 - Electrical connection 14

Commissioning and adjusting21Before starting up the system, check that the heating,hot water circuits are full and thoroughly vented.Check the p

Pagina 17 - Step1 Step3Step2

Commissioning and adjusting 22Air is initially released from the hot water and ventingmay be necessary. If bubbling sounds can be heardfrom the heat p

Pagina 18 - Electrical connection 16

Control23General information Menu Navigation The right-hand button on the control panel is used to open the desired menu. The left-ha

Pagina 19 - Electrical connection17

Control 24Menus Main Menu INFORMATION To open the main menu INFORMATION, press the right- or left-hand button once. To select the des

Pagina 20 - Electrical connection 18

Control25• OPERATION OFF Heat pump is turned off. The following text is displayed on the control panel: “OPERATION OFF “ If the heat pump will be

Pagina 21 - Electrical connection19

Control 26 Sub-Menu TEMPERATURE This menu shows the different temperatures of the heating system. All temperature changes registered over the

Pagina 22 - Electrical connection

Control27 Menus Menu Text Description Adjustable by: CMP.A ADD1 ADD 2 USER USER U

Pagina 23 - Commissioning and adjusting21

Contents1System descriptionPrinciple of operation ... 3Control panelLayout ...

Pagina 24 - Adjust heat medium pump

Control 28Before the Degree Minute reach - 60 (adjustable) ,the compressor is off, but when the Degree Minute reach - 60 (adjustable) ,the compressor

Pagina 25 - Control23

Sub-Menu OPERATING TIME OPERATION TIMEHEATPUMPADD1ADD2ADD3WARMWT2 H1 H0 H0 H0 H Table 3: Menu OPERATING TIME Menu Text Description Adjustable :

Pagina 26 - Control 24

Control 30 Most settings will be made by the installation contractor in connection with installation. Adjustments to be made regularly by the user are

Pagina 27 - Control25

Control31Adjustments to be made regularly Adjustment of the CURVE value The heat curve will be adjusted by the CURVE value. This value indicates

Pagina 28 - Control 26

Control 32Adjustments to be made regularlyWhen enter ‘Room heat’ mode, user could control compressor and electrical heater through regulate heat curve

Pagina 29 - Control27

Control33Adjustments to be made regularly Adjus tment of ROOM value As mentioned above, you can also adjust heat curve and indoor temperature by c

Pagina 30 - Control 28

Adjustments to be made regularly Adjustment of Part of the Heat Curve At outdoor temperatures between -5°C and +5°C part of the heat curve may

Pagina 31 - Control29

Adjustments to be made regularly Adjustment of the MIN and MAX value The MIN and MAX value is the lowest respectively highest value that is all

Pagina 32 - Control 30

Control 36Adjustments to be made regularly Graph of recent changes in TEMPERATURE All temperatures registered during the last hour can be vie

Pagina 33

Control37Maximum Return Line Temperature The maximum return line temperature, i.e. temperature of the water returning from the heating system, should

Pagina 34

AWA-SS series consists of a heat pump, water heater, electrical module, circulation pumps and a control sys-tem. AWA-SS series is connected to the Out

Pagina 35

Control 38Regular Checks Check of Operating Mode In the event of an alarm, The background light of LCD will flash and an alarm message will be di

Pagina 36 - Change of the value for CURVE

Control39Regular Checks Checking the Safety Valves Both safety valves of the heating system should be checked at least four times a year to prev

Pagina 37 - Control35

Control 40Alarm MessagesIn the event of an alarm message, try to re-start the unit with the safety switch. If this does not work, try to solve the pro

Pagina 38 - Control 36

Control41Terminology and Abbreviations Evaporate the evaporator, energy from the heat source is absorbed by the refrigerant passing through the evap

Pagina 39 - Control37

Description of the switch boardFunction Initial state A0 1AA MBA MSwitch boardA0 1 : Control the compressor;AA M : Control the water cyc

Pagina 40 - Check of Operating Mode

Dealing with malfunctions43FIGHTER 1220Close the shut-off valves in heating medium system.open the drain valve (73 , 74). A small amount ofwater runs

Pagina 41 - Control39

44 11132456791012131489Component placementPlease Note :The picture for reference only !

Pagina 42 - Alarm Messages

262324255556575859606162636465666769151817162019212268RTComponent placement45273133323435373638394047464842505153525428OCTOUTP43293041444549Please Not

Pagina 43 - Control41

Component placement3X400 V / 3 / 50 HZ230 V /50 HZ7071707146Please Note :The picture for reference only !

Pagina 44 - Initial state

List of components37 Adjustable pressure switch38 Valve for adjustable pressure switch472 Right side board3 Left side board4 Glass upper door5 Glass l

Pagina 45 - Dealing with malfunctions

System description3Unit Description In order to get the best results from the climate system AWA-SS series you should read through the section For the

Pagina 46 - Component placement

Dimensions and setting-out coordinates7206705030-5045527078904804823842086254018005446060054440Dimensions48

Pagina 47 - Component placement45

DimensionsDimensions of the AWA-SS-6 outdoor unit69 0830310720Dimensions of the AWA-SS-10 outdoor unit77088036080049Dimensions of the AWA-SS-8 outdoor

Pagina 48

DimensionsDimensions of the AWA-SS-12 outdoor unitDimensions of the AWA-SS-16 outdoor unit120083031012301220930390125050

Pagina 49 - (OFF 4.2MPa/ON 3.6MPa)

AccessoriesFIGHTER 1220Outside air temperature sensorRoom temperature sensor78778079Enclosed kit818251

Pagina 50 - Dimensions

Technical specificationsTechnical specifications 230V / 3 x 400 V52Operating curr. incl. immersion heater 6 / 9 kW (A)Connection heating flow

Pagina 51

System description 4Principle of heat pumpA heat pump can exploit the energy contained in natural heat sources. Or, to put it differently, the heat pu

Pagina 52

Control panel5DisplayLeft buttonLayoutCDbuttonExplanation Power On/OffA UpbuttonFDownbutton Control Panel The control panel of AWA-SS

Pagina 53 - Accessories

Control panel 6Functions The control computer is operated with the help of a user friendly menu system that is displayed on the contr ol panel. Th

Pagina 54 - Technical specifications

General information for the installer7Current regulations require the heating installation tobe inspected before it is commissioned. The inspec-tion m