11/04/08
1
PD-60356
IR3802MPBF
HIGHLY INTEGRATED 4A
WIDE-INPUT VOLTAGE, SYNCHRONOUS BUCK REGULATOR
Features
Wide Input Voltage Range 2.5V to 21V
Wide Output Voltage Range 0.6V to 12V
Continuous 4A Load Capability
600kHz High Frequency Operation
Programmable Over-Current Protection
Hiccup Current Limit
Precision Reference Voltage (0.6V)
Programmable Soft-Start
Pre-Bias Start-up
Thermal Protection
Thermally Enhanced Package
Small Size 5mmx6mm QFN
Pb-Free (RoHS Compliant)
Fig. 1. Typical application diagram
Description
The IR3802 SupIRBuck
TM
is an easy-to-use, fully
integrated and highly efficient DC/DC regulator.
The onboard switching controller and MOSFETs
make the IR3802 a space-efficient solution,
providing accurate power delivery for low output
voltage applications.
The IR3802 operates from a single 4.5V to 14V
input supply and generates an output voltage
adjustable from 0.6V to 0.75*Vin at loads up to 4A.
A versatile regulator offering programmability of
startup time, power good threshold and current
limit, the IR3802’s fixed 600kHz switching
frequency allows the use of small external
components.
The IR3802 also features important protection
functions, such as Pre-Bias startup, hiccup
current limit and thermal shutdown to provide the
required system level security in the event of fault
conditions.
SupIRBuck
TM
Applications
Game Consoles
Set-top Boxes
Graphics Cards
LCD TVs
Desktop PCs
Distributed Point-of-Loads
Embedded Systems
Computing Peripheral Voltage Regulators
Vista de pagina 0
1 2 3 4 5 6 ... 20 21

Indice de contenidos

Pagina 1 - SupIRBuck

11/04/081PD-60356IR3802MPBFHIGHLY INTEGRATED 4AWIDE-INPUT VOLTAGE, SYNCHRONOUS BUCK REGULATORFeatures• Wide Input Voltage Range 2.5V to 21V• Wide Ou

Pagina 2

11/04/0810PD-60356IR3802MPBFOver-Current ProtectionThe over-current protection is performed by sensing current through the RDS(on)of the low side MO

Pagina 3

11/04/0811PD-60356IR3802MPBFApplication InformationDesign Example:The following example is a typical application for the IR3802. The application cir

Pagina 4

11/04/0812PD-60356IR3802MPBFInput Capacitor SelectionThe input filter capacitor should be selected based on how much ripple the supply can tolerate

Pagina 5

11/04/0813PD-60356IR3802MPBFFeedback CompensationThe IR3802 is a voltage mode controller; the control loop is a single voltage feedback path includi

Pagina 6

11/04/0814PD-60356IR3802MPBFTo cancel one of the LC filter poles, place the zero before the LC filter resonant frequency pole:Use equations (15) and

Pagina 7

11/04/0815PD-60356IR3802MPBFBased on the frequency of the zero generated by the output capacitor and its ESR versus crossover frequency, the compens

Pagina 8

11/04/0816PD-60356IR3802MPBFProgramming the Current-LimitThe Current-Limit threshold can be set by connecting a resistor (RSET) from drain of the lo

Pagina 9 - Soft-Start

11/04/0817PD-60356IR3802MPBFTypical Application for IR380212V to 1.8V @ 4AFig.16: Typical Application circuit for 12V to 1.8V at 4A using ceramic ou

Pagina 10 - PD-60356

11/04/0818PD-60356IR3802MPBFPCB Metal and Components PlacementThe lead lands (the 11 IC pins) width should be equal to the nominal part lead width.

Pagina 11 - Application Information

11/04/0819PD-60356IR3802MPBFSolder ResistIt is recommended that the lead lands are Non Solder Mask Defined (NSMD). The solder resist should be pulle

Pagina 12

11/04/082PD-60356IR3802MPBFPACKAGE INFORMATION5mm x 6mm POWER QFNFig. 2: Package outline (Top view)W/C2θW/C35θoPCBJoJA==-400015IR3802MTRPBFM750PARTS

Pagina 13

11/04/0820PD-60356IR3802MPBFStencil Design• The Stencil apertures for the lead lands should be approximately 80% of the area of the lead lads. Reduc

Pagina 14 - IR3802MPBF

11/04/0821PD-60356IR3802MPBFIR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105TAC Fax: (310) 252-7903This

Pagina 15

11/04/083PD-60356IR3802MPBFBlock DiagramFig. 3. Simplified block diagram of the IR3802.

Pagina 16

11/04/084PD-60356IR3802MPBFPin DescriptionPins 4, 5 and 15 need to be connected together on system board. Pin Name Description 1 NC No Connect 2 F

Pagina 17

11/04/085PD-60356IR3802MPBFRecommended Operating ConditionsParameter Symbol Test Condition Min TYP MAX Units Power Loss Power Loss Ploss Vcc=Vin=1

Pagina 18

11/04/086PD-60356IR3802MPBFNote1: Continuous output current determined by input and output voltage setting and the thermal environment.Note2: Cold t

Pagina 19

11/04/087PD-60356IR3802MPBFTYPICAL OPERATING CHARACTERISTICS (-40oC - 125oC)Icc(static)7.08.09.010.011.012.013.0-40 -20 0 20 40 60 80 100 120Temp[oC

Pagina 20

11/04/088PD-60356IR3802MPBFCircuit DescriptionTHEORY OF OPERATIONThe IR3802 is a voltage mode PWM synchronous regulator and operates with a fixed 60

Pagina 21

11/04/089PD-60356IR3802MPBFSoft-StartThe IR3802 has programmable soft-start to control the output voltage rise and limit the inrush current during s